Operator Messages Manual
Chapter 39 FCS Monitor Messages
The messages in this chapter are generated by the FCS Monitor
subsystem. The subsystem ID displayed by these messages includes FCSM
as the subsystem name. | | | | | NOTE: Negative-numbered messages are common to most subsystems. If
you receive a negative-numbered message, see Chapter 15. For a discussion of compressed element identifiers for disk
drive enclosures, see “Compressed Identifiers for Disk Drive Enclosure Elements”.Of the two FCSA adapters that connect a server to a disk drive
enclosure chain, the canonical adapter is the adapter with the smaller
group, or module, or slot, or SAC, taken in that order, The canonical
adapter group, module identify a disk drive enclosure and its elements.
See “Canonical Naming Convention”. | | | | |
A disk drive enclosure is normally connected by two Fibre Channel
cables to two different FCSA adapters. These adapters can be located
in two different IOAM modules or enclosures. The FCS monitor process
identifies disk drive enclosures and their elements through their
group, module and slot designations, which are numbers derived from
the I/O Path. Because the FCS monitor process recognizes each element
through two different adapters, each element could seem to have two
different identities. To avoid this situation, the FCS monitor process identifying
a disk drive enclosure and its elements by recognizing only that fibre
channel cable whose I/O path values are smaller; that is, the identity
of the disk drive enclosure and its elements is based on the cable
that has the smaller group number, or the smaller module number, or
the smaller slot number, or the smaller SAC number, in that order.
HP refers to this I/O path as the “canonical path” and
to its constituent group, module, and slot numbers as “canonical.” The FCS Monitor process uses a compression algorithm to identify
elements of a disk drive enclosure containing M2801 fibre channel
disks. The FCS Monitor process converts the six number I/O path (group,
module, slot, SAC, shelf, and bay) to a three-number designation. The algorithm is: Table 39-1 Compression Algorithm for Disk Drive Enclosure Element Identification Segment of I/O Path | Disk Drive Enclosure
Element Identifier |
---|
group | group | module = 2 or 3 | (module * 100) + (slot * 10) + SAC Number | slot= 1 through 5 | (100 * shelf) + Bay Number | sac = 1 or 2 | | shelf = 1 through 4 if daisy-chained;
1 if a single disk drive enclosure | | bay = 0 through 99 | |
This is an example three-number designation: 1 FCSM Monitor starts. Canonical path: canoGroup,canoModule,canoSlot Non-canonical path: Group,Module, Slot | canoGroup | is the compressed group number of the canonical adapter. | canoModule | is the compressed module number of the canonical adapter. | canoSlot | is the compressed slot number of the canonical adapter. | Group | is the compressed group number of the second path
adapter. | Module | is the compressed module number of the second path
adapter | Slot | is the compressed slot number of the second path adapter |
Cause The FCS Monitor process in a CPU receives a request to start
monitoring a disk-drive enclosure chain Effect The FCS Monitor process starts monitoring a disk-drive enclosure
chain. Recovery This is an informational event message only; no corrective action
is needed. |
2 FCSM Monitor stops. Canonical path: canoGroup,canoModule,canoSlot Non-canonical path: Group,Module,Slot | canoGroup | is the compressed group number of the canonical adapter. | canoModule | is the compressed module number of the canonical adapter. | canoSlot | is the compressed slot number of the canonical adapter. | Group | is the compressed group number of the second path
adapter. | Module | is the compressed module number of the second path
adapter | Slot | is the compressed slot number of the second path adapter |
Cause The FCS Monitor process in a CPU receives a request to stop
monitoring a disk-drive enclosure chain. Effect The FCS Monitor process stops monitoring a disk-drive enclosure
chain. Recovery This is an informational event message only; no corrective action
is needed. |
3 FRU TYPE NUMBER: type. type is inserted at (group,module,slot). Node WWN for type: 0x wwn. | type | is the device type of disk drive enclosure element.
Possible values are: | group | is the compressed group number. | module | is the compressed module number. | slot | is the compressed slot number. | wwn | is the world wide name of the element. |
Cause A disk drive enclosure element of the type indicated by type is present in the disk drive enclosure. Effect The FCS Monitor process begins monitoring the element. Recovery This is generally an informational event message only. No corrective
action is needed unless the element has not been physically inserted,
in which case the cause of the event should be investigated. |
4 FRU TYPE NUMBER: type. <type> is removed at group,module,slot). Node WWN
for type: 0xwwn | type | is the device type of disk drive enclosure element.
Possible values are: | group | is the compressed group number. | module | is the compressed module number. | slot | is the compressed slot number. | wwn | is the world wide name of the element. |
Cause A disk drive enclosure element of the type indicated by type is not longer present in the disk drive enclosure. Effect FCS Monitor process stops monitoring the element. Recovery This is generally an informational event message only. No corrective
action is needed unless the element has not been physically removed. |
5 Disk State Change at (group,module,slot). Node WWN for disk element: 0xwwn Old disk status: 0xstatus Old
disk status1: 0xstatus1 Old disk status2:
0xstatus2 New disk status: 0xstatus New disk status1: 0xstatus1 New disk status2: 0xstatus2 | group | is the compressed group number. | module | is the compressed module number. | slot | is the compressed slot number. | wwn | is the world wide name of the element. | status | contains the common status for a disk in a disk drive
enclosure. | status1 | is disk status byte 1. | status2 | is disk status byte 2. |
Cause A status change for a disk element in a disk drive enclosure. Effect Status of a disk element has changed. Recovery This is an informational event message only; no corrective action
is needed. |
6 Status for a blower is changed. Blower GMS: group,module,slot Old blower status: 0xstatus Old blower status1: 0xstatus1
New blower status: 0xstatus New blower
status1: 0xstatus1 | group | is the compressed group number. | module | is the compressed module number. | slot | is the compressed slot number. | status | contains the common status for blower. | status1 | is blower status byte 1. |
Cause This event is generated by FCSMON whenever the status of a Fibre
Channel disk module (FCDM) blower changes. The status could have changed
from good to bad or vice versa (if the change is in the Status byte). This event indicates a change in the
LED state for the blower or the speed of blower (if the change is
in the Status1 byte). Effect The status of a blower element in an FDCM has changed. Recovery If the status change is in status byte, check the OSM Service Connection
for a Hardware Error alarm on the blower. This alarm indicates that
you must replace the blower. If the status change is in status1 byte,check the LED state of the blower
in the OSM Service Connection. This message indicates a change in
the blower’s LED status or speed. This message is informational
only. |
7 Status for a Power Supply is changed Power
supply GMS: group,module,slot Old Power Supply status: 0xstatus Old Power Supply status1: 0xstatus1 Old Power Supply status2: 0xstatus2 New Power Supply status: 0xstatus New Power Supply status1: 0xstatus1 New Power Supply status2: 0xstatus2 | group | is the compressed group number. | module | is the compressed module number. | slot | is the compressed slot number. | status | contains the common status for a power supply in a
disk drive enclosure. | status1 | is power supply status byte 1. | status2 | is power supply status byte 2. |
Cause A status change occurred for a power supply element in a disk
drive enclosure. Effect The status of a power supply element has changed. Recovery This is an informational event message only; no corrective action
is needed. |
8 Status for an EMU is changed. EMU GMS: group,module,slot Old EMU status: 0xstatus Old EMU status1: 0xstatus1 New
EMU status: 0xstatus New EMU status1:
0xstatus1 | group | is the compressed group number. | module | is the compressed module number. | slot | is the compressed slot number. | status | contains the common status for the EMU. | status1 | is EMU status byte 1. |
Cause A status change occurred for an EMU element in a disk drive
enclosure. Effect The status of an EMU element has changed. Recovery This is an informational event message only; no corrective action
is needed. |
9 Status for an IO module is changed. IO module
GMS: group,module,slot Old IO module status: 0xstatus Old IO module status1: 0xstatus1 New IO module status: 0xstatus
New IO module status1: 0xstatus1 | group | is the compressed group number. | module | is the compressed module number. | slot | is the compressed slot number. | status | contains the common status for the I/O module. | status1 | is I/O module status byte 1. |
Cause A status change occurred for an I/O module in a disk drive enclosure. Effect The status of an I/O module has changed. Recovery This is an informational event message only; no corrective action
is needed. |
10 Sensor Status change for environment
element at (group,<module,slot). Element is transceiver, voltage
sensor, current sensor or temperature sensor. Enclosure WWN:
0xwwn | group | is the compressed group number. | module | is the compressed module number. | slot | is the compressed slot number. | wwn | is the world wide name of the disk drive enclosure. |
Cause A transceiver, voltage sensor, current sensor, or temperature
sensor element in a disk drive enclosure changed status. Effect The status of a sensor element has changed. Recovery This is an informational event message only; no corrective action
is needed. |
11 Enclosure is inserted at (group,module,slot). Disk present info: 0xdiskpresent Disk status info : 0xdiskstatus | group | is the compressed group number. | module | is the compressed module number. | slot | is the compressed slot number. | diskpresent | is a bit map indicating which disk are present in
an enclosure chain. | diskstatus | is a bit map indicating the status of the disks. |
Cause A disk drive enclosure monitored by the FCS Monitor process
is being updated in the PCT with new element entries. Effect None. Recovery This is an informational event message. Corrective action is
needed only if the enclosure is inserted, in which case, the event
should be investigated to determine whether an underlying problem
exists. |
12 Enclosure at (group,module,slot) is removed. | group | is the compressed group number. | module | is the compressed module number. | slot | is the compressed slot number. |
Cause The FCS Monitor process has stopped monitoring a disk drive
enclosure and has updated the PCT by deleting the element entries Effect None. Recovery This is an generally informational event message. Corrective
action is needed only if the enclosure has not been physically removed,
in which case, the event should be investigated to determine whether
an underlying problem exists. |
13 EMU Access State Change : Path from FCSA
(sac_group,sac_module,sac_slot) to EMU (group,module,slot). Old EMU Access State: 0xstatus
New EMU Access state: 0xstatus Reason
code : code | sac_group | is the compressed FCSA group number. | sac_module | is the compressed FCSA module number. | sac_slot | is the compressed FCSA slot number. | group | is the compressed EMU group number. | module | is the compressed EMU module number. | slot | is the compressed EMU slot number. | status | specifies the common status for an EMU in a disk drive
enclosure: | code | is the reason code for a loss of communication:. |
Cause Access to the EMU through a particular disk in a disk drive
enclosure has changed. Effect Transitions from Unknown to Up are informational only. Transitions
to Bypassed indicate that the particular disk drive has been bypassed
by an operator command or by the disk drive enclosure. Transitions
to Down indicate loss of communication with the EMU through
a particular disk drive. Transitions from Down to Up indicate that
communication with the EMU through a particular disk drive has been
restored. Recovery Transitions to Up are informational only; no corrective action
is needed. Transitions to Bypassed not initiated by an operator command
should be investigated. Transitions to Down indicate loss of communication
to the EMU and should be investigated; the reason code indicates the
reason for loss of communication. |
14 New path (added_group,added_module,added_slot) is added. Existing path: group,module,slot | added_group | is the compressed path group number for the added
path. | added_module | is the compressed path module number for the added
path. | added_slot | is the compressed path slot number for the added path. | group | is the compressed EMU group number for the existing
path. | module | is the compressed EMU module number for the existing
path. | slot | is the compressed EMU slot number for the existing
path. |
Cause An FCSA adapter path to a disk drive Enclosure chain has been
added, replacing a previously existing path to the chain. Effect A new controller has been added to an existing disk drive enclosure
chain. Recovery This is an informational event message only; no corrective action
is needed. |
15 Path (deleted_group,deleted_module,deleted_slot) is deleted. Remaining path: group,module,slot | deleted_group | is the compressed group number for the deleted path. | deleted_module | is the compressed module number for the deleted path. | deleted_slot | is the compressed slot number for the deleted path. | group | is the compressed group number for the existing path. | module | is the compressed module number for the existing path. | slot | is the compressed slot number for the existing path. |
Cause An FCSA adapter path to a disk drive enclosure chain has been
removed, leaving one remaining path to the chain. Effect An adapter has been removed. Recovery This is an informational event message only; no corrective action
is needed. |
16 Path Status Change. Path from FCSA (sac_group,sac_module,sac_slot> to EMU group,module>,slot Old Path Status: 0xstatus New Path
status: 0xstatus Reason code : <code> | sac_group | is the compressed FCSA group number. | sac_module | is the compressed FCSA module number. | sac_slot | is the compressed FCSA slot number. | group | is the compressed EMU group number. | module | is the compressed EMU module number. | slot | is the compressed EMU slot number. | status | specifies the common status for an EMU in a disk drive
enclosure: | code | is the reason code for the loss of communication. |
Cause The access or the FCS Monitor process to the EMU has changed. Effect Transitions from Unknown to Up are informational only. Transitions
to Down indicate loss of communication with the EMU through all disk
drives. Transitions from Down to Up indicate that communication with
the EMU through some disk drive has been restored. Recovery Transitions to Up are informational event message only; no corrective
action is needed. Transitions to Down indicate loss of communication
with the EMU and should be investigated; the reason code indicates
the reason for loss of communication. |
17 FCSM EMU firmware upgrade. EMU GMS (group,module,slot) Reason Code: code Download Cmpl Status: 0xcompl_status | group | is the compressed EMU group number. | module | is the compressed EMU module number. | slot | is the compressed EMU slot number. | code | is the reason code for the failure: | comp_status | specifies the EMU firmware upgrade completion status: |
Cause An attempt to update the EMU in a disk drive enclosure has
completed. The EMU firmware completion status indicates the success
or failure of the firmware update. In the case of failure, the reason
code gives additional information. Effect Either the EMU firmware has been updated, or the firmware update
has failed. Recovery If the EMU firmware update is not successful, it should be retried
after an investigation of the cause of the failure indicated by the
completion status and reason code. |
20 TANDEM.FCSM.H01 0000020 FCSM generic_error. EMU GMS (group,module,slot) | generic_error | contains generic error information. | group | is the compressed EMU group number. | module | is the compressed EMU module number. | slot | is the compressed EMU slot number. |
Cause the FCS Monitor process has detected an error condition more
substantive than a descriptive event. This event message contains
generic error information that can be used for diagnostic purposes. Effect The effect is indicated in generic_error. Recovery Contact your service provider. |
21 FCSM IO error event with SMD additional status.
EMU GMS (group,module,slot) Device ID: 0xdevice Controller number: 0xcontroller_number Port number: 0xport | group | is the compressed EMU group number. | module | is the compressed EMU module number. | slot | is the compressed EMU slot number. | device | the identifier of the failing device. | controller_number | is the FCSA identification number. | port | is the port number of the enclosure. |
Cause The FCS Monitor process has detected an I/O error. This event
message provides I/O error information and SMD additional status,
such as Servernet error, adapter error, or disk error. Effect None. Recovery Contact your service provider. |
22 FCSM IO error event with SCSI sense. EMU
GMS (group,module,slot) Sense Error Code: 0xsense_code sd-fm-eom-ili-sense Key: 0xsense_key Additional Sense Code: 0xadditional_code Additional Sense Code Qual: 0xadditional_sense_code_qual | group | is the compressed EMU group number. | module | is the compressed EMU module number. | slot | is the compressed EMU slot number. | sense_code | is the SCSI sense code | sense_key | is the SCSI sense key. | additional_code | is additional SCSI sense code information. | additional_sense_code_qual | is the additional sense code qualifier (ASCQ). |
Cause The FCS Monitor process has detected an I/O error. This event
message provides the I/O error information and SCSI status. Effect The effect is indicated by sense_code, sense_key, and additional_code., and additional_sense_code_qual. The
FCS Monitor process will recover appropriately. Recovery Contact your service provider. |
23 Duplicate Shelf Event. EMU GMS (group,module,slot) | group | is the compressed EMU group number. | module | is the compressed EMU module number. | slot | is the compressed EMU slot number. |
Cause Two or more disk drive enclosures in the same daisy chain have
the same shelf number. Effect The FCS Monitor process does not monitor both disk drive enclosures.
The FCS Monitor process will monitor only the first disk drive enclosure
discovered with the shared shelf number. Recovery Check for a missing or damaged ID expander cable between the
disk drive enclosures on the daisy chain. After the problem has been
corrected, stop and restart the FCS Monitor so that it will rediscover
the shelf numbers for the disk drive enclosures on the daisy chain. |
|