Chapter 48 KRN (Kernel Subsystem Manager) Messages

The messages in this chapter are generated by the Kernel Subsystem Manager subsystem. The subsystem ID displayed by these messages includes KRN as the subsystem name.

NOTE: Negative-numbered messages are common to most subsystems. If you receive a negative-numbered message that is not described in this chapter, see Chapter 15.


1

System configuration mismatch detected

Cause  The system was loaded with a system configuration database containing mismatch values compared to the information stored in the device processor.

Effect  The system uses the values stored in the service processor.

Recovery  Use a Subsystem Control Facility (SCF) command to correct the content of the system configuration and/or the service processor. If needed, reload the system.



2

System power down has initiated.

Cause  An operator requested a system power down.

Effect  The system performs system shutdown and then powers itself off.

Recovery  This is an informational message only; no corrective action is needed.



3

System failed to backout name reservation records.

Cause  The KRN detected a process name being used while it is reserving process names. This caused KRN to remove previously reserved process name.

Effect  The system configuration database is inconsistent.

Recovery  See the SCF Reference Manual for the Kernel Subsystem for recovery.



4

NO ALLPROCESSORS record found in system configuration database, default ALLPROCESSORS record added

Cause  Because no ALLPROCESSORS record was found in the system configuration database, a default ALLPROCESSORS record was added. The error occurs when the system is loaded from CONFBASE.

Effect  None.

Recovery  If you want to change the default value, use the ALTER SUBSYSTEM ($ZZKRN) command. For more information, see the SCF Reference Manual for the Kernel Subsystem.



7

No KRN_SUBSYS record found in system configuration database, default KRN_SUBSYS record added.

Cause  A default KRN_SUBSYS record was added to the system configuration database because no KRN_SUBSYS record was found in the system configuration database. This message occurs when the system is loaded from CONFBASE.

Effect  None.

Recovery  This is an informational message only; no corrective action is needed. If you want to change the default values, use the SCF ALTER SUBSYS command (for more information about this command, see the SCF Reference Manual for the Kernel Subsystem).



8

Size of DCT altered to SMALL (32766) in system configuration. The new DCT Size takes effect immediately.

Cause  You used the SCF ALTER SUBSYS command to change the size of the DCT to SMALL (32,766 entries).

Effect  None.

Recovery  This is an informational message only; no corrective action is needed.



9

Size of DCT altered to MEDIUM (65375) in system configuration. The new DCT Size takes effect immediately.

Cause  You used the SCF ALTER SUBSYS command to change the size of the DCT to MEDIUM (65,375 entries).

Effect  None.

Recovery  This is an informational message only; no corrective action is needed.



11

No Krn_Subsys2 record found in system configuration database, default Krn_Subsys2 record added.

Cause  A timer granularity record was added to the configuration database.

Effect  None.

Recovery  This is an informational message only; no corrective action is needed.



12

Timer Granularity value is altered from TIMER_GRANULARITY  option to TIMER_GRANULARITY  option.

where TIMER_GRANULARITY option

is one of FORCE_ORDINARY, DEFAULT_ORDINARY, DEFAULT_FINE, or FORCE_FINE options.

Cause  A timer granularity record was altered in the system and the configuration database.

Effect  None.

Recovery  This is an informational message only; no corrective action is needed.